this post was submitted on 10 Aug 2024
1 points (100.0% liked)

Technology

59672 readers
3060 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related content.
  3. Be excellent to each another!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, to ask if your bot can be added please contact us.
  9. Check for duplicates before posting, duplicates may be removed

Approved Bots


founded 1 year ago
MODERATORS
 
you are viewing a single comment's thread
view the rest of the comments
[–] mox@lemmy.sdf.org 0 points 3 months ago* (last edited 3 months ago) (2 children)

Using commercial off the shelf technology without proper testing and certification is absolutely cutting corners. See: Kaprun disaster.

I just read the wikipedia article; thanks for mentioning it.

I'm not sure it's a good example of your point, though. Notably:

the cause was the failure, overheating and ignition of a fan heater in the conductor's compartments which was not designed for use in a moving vehicle.

The onboard electric power, hydraulic braking systems, and fan heaters intended for domestic use increased the likelihood of fire.

The fan heater is the only off-the-shelf technology listed here, and there's no suggestion that it was part of the train's design. It seems likely that a train conductor brought it on board to keep the compartment warm through the workday. Still a bad idea in a train, especially on a 30° slope, but not an example of the designers cutting corners.

[–] deranger@sh.itjust.works 0 points 3 months ago* (last edited 3 months ago)

It’s an example of uncertified consumer grade equipment used in a commercial environment to disastrous results, outside of its original designed purpose. It’s one of the most well known examples of why you don’t use consumer grade hardware in a commercial/industrial setting.

It was not brought on board by the conductor or someone else, it was permanently installed in the train in place of commercial grade heaters they couldn’t source. It’s not a personal space heater if that’s what you’re picturing. It was a permanent part of the train, in the wall.

I’d argue it is an example of cutting corners, they didn’t want to find / pay more for commercial grade heaters. It was not compliant with the original design nor fire safety standards.

[–] llii@discuss.tchncs.de 0 points 3 months ago (1 children)

It was not a train conductor that brought it with him, it was build into the train by the train manufacturer. See this page: https://155.at/der-heizluefter/

[–] mox@lemmy.sdf.org 0 points 3 months ago* (last edited 3 months ago) (1 children)

it was build into the train by the train manufacturer.

What makes you think the train manufacturer did it? Is that on record someplace? Because the installation and materials don't look at all like the surrounding work. Looks more like a handyman hack job. Now that I've seen the photos, I'm curious about what actually happened there.

[–] a_wild_mimic_appears@lemmy.dbzer0.com 0 points 3 months ago (1 children)

It was not the train manufacturer, but a body shop (Swoboda Karosserie- und Stahlbau GesmbH, now Carvatech), which was recruited by the Gletscherbahn Kaprun (GBK) for renovations. It might have not had so large repercussions if anyone of the actors during those renovations had done his job correctly tho:

  • the model chosen was for household use and chosen because the recommended fan heater was unavailable
  • other departments of Swoboda (and because of that, everyone else) were not informed about this change, even leading to sending out the documentation of the recommended fan heater to GBK
  • the fan heater was mounted in a way that allowed liquids to leak inside of it
  • it was mounted directly in front of the hydraulics, which contained flammable liquids
  • those hydraulics were redone during the renovations by Mannesmann-Rexroth AG (now Bosch Rexroth AG), and were done using plastic pipes and were not appropriately encased.
  • They started melting because of the malfunctioning heater, spraying flammable oil at 190 bar into the fire
  • the dropping oil pressure caused the train to automatically break
  • but the hydraulics were also needed to open the goddamn doors.

On top of all that, because the cable cars were made of aluminium, they were deemed inflammable. This did not take into account that any installed equipment or passengers and their luggage might NOT be fireproof.

This lead to: no fire exits, no emergency signage, no training for employees how to react in case of fire.

it was a single malfunctioning heater, but the Kaprun disaster had many fathers.

I found a nice paper regarding the different actors written by a student of the University of Virginia here, well sourced.

[–] mox@lemmy.sdf.org 0 points 3 months ago