Hey folks, looking for some advice because I don't know how to proceed.

This house came with vinyl siding and I noticed rot under it. The rot terminates up high behind where this soffit meets with the exterior wall. I need to get in here to figure out how water is getting in and then make necessary repairs, but the soffit is really in the way.

I've already removed the rot lower down - I had to remove vinyl siding, a layer of foam board, a layer of rotten OSB, the original rotten siding, and the original rotten sheathing. All of those layers are still present behind this soffit.

When I take the soffit vent off, there's a layer of OSB directly above it. Really don't know how to gain access here.

Any ideas?

you are viewing a single comment's thread
view the rest of the comments
[โ€“] ikidd@lemmy.world 8 points 1 year ago (1 children)

Step flashing and diverter at the end isn't working right. The last piece of step flashing above the gutter should have a bent out piece to get water running down the wall above to go into the gutter and not just run down the wall. I'd also be very suspicious the siding isn't installed correctly there as well as it shouldn't let water behind it.

I'd get an exteriors contractor to come and look at it, and see if they can bring the two problems together to be fixed.

[โ€“] WantsToPetYourKitty@lemmy.world 3 points 1 year ago* (last edited 1 year ago)

No diverter is present there at all. There's a bunch of things going on here that could be causing this problem and I think it would be best to address all of them at once:

  • No diverter
  • No drip edge present along gutter, and I've seen water drip from soffit vents. It's possible water is coming into the damaged area from where the soffit meets the wall
  • Vinyl siding was installed over original wood composite. It's questionable whether the step flashing is effective given the setup
  • Gutter potentially too small - I have to clean it out like 6 times a year even with gutter guards over most of it